1 Blink followed by 2 Sec. Pause- 1 Hr lockout |
2 Blinks followed by 2 Sec. Pause- Pressure Switch is Open |
3 Blinks followed by 2 Sec. Pause- Limit Switch is Open |
4 Blinks followed by 2 Sec. Pause- Pressure Switch is Closed |
5 Twinning fault |
|
Auxiliary limit switch: located on warm
air blower housing n monitor return air To |
|
|
Draft safeguard switch: NC, open when detect flu
gas leaking |
|
Manifold pressure: 11" of a manometer, connecting
to gas valve to check |
|
Limit switch: NC. When furnace is overheated
[200_250oF], it open to and close main valve gas |
Helical bimetal: positioned next to the heat exchanger
control Limit sw and fan sw |
|
Flame proving devices: Thermocouple[15_30 mV],,
thermopile, bimetallic strip, liquid-filled remote bulb. |
Igniters: Intermittent pilot (IP), Diewct-spark
ignition (DSI), Hot surface ignition(HSI) |
Gas Pressure : 3.5 WC |
Pressure SW: NO, 24v terminals continuity when reduced
draft fan working |
|
|
|
|
|
|
|
|
|
|
|