Test Error Codes
(1) ,
(2) |
Mod |
Code |
Problem |
Could be |
|
Belt replacement |
|
|
from the back panel. Not from |
ASKO |
|
|
|
|
Frigidaire |
Electrical
Gas Wiring |
|
|
|
GE stackable |
DSXH47EG1WW |
: test heater: Yl [motor block terminal]_ Bl [2
wire connector to MB]=11_15Ω |
GE |
3 stars screw |
Heater |
WH_orther color (opposite side) of a 4 terminal
sensor [42Ω]
connecting to High Limit T'stat, under 37Ω=>
bad. This model has heater with double coils [42Ω=21Ω*2]. cost $85 for
heater. Move drum forward to get the drum out. |
Fisher Paykel |
Top load dryer |
Run |
Not heating |
pry 2 small plastic knobs both side, release 4 screws, press
reset red switch at bottom. Try, not working, continue check other elements |
|
|
LG manual |
Not turn on but interior light: check
T'stat fuse, door switch, ctrl board. |
Maytag Performa |
Old |
|
No power |
Thermo fuse closed to heater or Timer |
|
|
KM new model |
Turning+not heat: T'stats, heater are OK=>
Contrl board is bad |
KM Stackable |
Wiring |
Sears/Kenmore HE3_ F01 Error code |
Bad board: soldering between relay (bad pin) and
K2 (good pin) |
WP Duet |
Remove ctrl panel: release 4 screws in the back;
Remove drum: release one side of cabinet |
|
Motor not working+Not heating+Counting down:
fuse, Control board |
WP electric |
Most new model |
Thermal fuse is
wired in series with drive motor, wiring,
Motor test
FrontlintWiring, Motortest2,
W10436308.pdf Analog
Timer Timer
WPW10185982 |
|
Count down, not run=> fuse, contrl board, motor; |
WP F01 Error |
|
WP electric old model |
Not heat: check timer: BK_BU/BK_RD must be
continuity, The last is dryness ctrl board (2 resistors look bad color
8558178) |
WP electric |
Autodry not move: |
240v inlet at dryer motor=>Tmer OK, Cycling T'stat bad
or vice versa |
Frigidaire gas |
Sequences: Cạch rất lớn igniter turn on,
Cạch gas on, cạch gas off |
WP gas |
KenmoreEllit,
Amiral |
|
Not heating |
(1))Gas valve solenoids: 2 pin=[1kΩ_
2kΩ]; 3 pin=> 1_3=[500_1kΩ]; 1_2[1.3KΩ]; (2) Flame sensor= 0Ω;
igniter
[60Ω]; 2 wire coming down=110V; Heater Relay on ctrl panel, Circuit
Board, Timer, Thermal fuse ( is wired series with gas valve,
wiring) |
SS Electric |
Access: Top panel, pry and lift up out the
display screen, remove two screws outside in lint filter, lift up the door
out and lay on top. |
SS Electric |
Not run, Power ok |
: Thermostat on blower, motor safety
switch, Control board, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|